{"product_id":"100061177-qo-15-amp-single-pole-circuit-breaker","title":"Square D QO 15 Amp Single-Pole Circuit Breaker, Plug-On, 120\/240V, 10kA (QO115CP)","description":"\n    \u003ch1\u003eQO115CP 15A Single-Pole Circuit Breaker\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eThis Square D QO thermal-magnetic breaker delivers reliable overload and short-circuit protection for 120\/240V circuits. The plug-on design fits QO load centers and CSEDs using one space, with a 10kA interrupt rating and Visi-Trip indicator for quick troubleshooting.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThermal-Magnetic Protection:\u003c\/strong\u003e Guards circuits against overloads and short-circuits with dependable trip performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-On Installation:\u003c\/strong\u003e Simple, secure fit in Square D QO load centers and CSEDs using one space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisi-Trip Indicator:\u003c\/strong\u003e Easily identify tripped breakers via the red midpoint handle indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Single-Pole Design:\u003c\/strong\u003e 15A, 120\/240V rating with 10kA interrupt capacity for residential applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Durability:\u003c\/strong\u003e ANSI certified construction backed by a limited lifetime warranty in QO load centers\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/8c69f2e1-263e-4d7b-a4e1-4c285423052f_da9dc462-9c4f-4754-85dc-8a236a8eb7f0.pdf?v=1763435917\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed; ANSI Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D QO load centers, CSEDs, and NQOD panelboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisi-Trip Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Will this fit my panel?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is compatible with Square D QO load centers and CSEDs that accept single-pole QO breakers and require one space.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the interrupt rating?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e 10,000 AIC at 120\/240 VAC.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How do I know if it has tripped?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The Visi-Trip feature moves the handle to a midpoint with a red indicator to quickly identify the tripped breaker.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What type of trip mechanism is used?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Thermal-magnetic trip unit for both overload and short-circuit protection.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is it UL listed?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is UL Listed and ANSI certified.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eA Sleek, Compact Guardian for Your Power\u003c\/h2\u003e\n    \u003cp\u003eThis streamlined breaker brings quiet confidence to a panel, marrying crisp functionality with minimalist form. The signature Visi-Trip window adds a subtle, modern cue that feels both intelligent and refined. Pair it with a well-organized QO load center to create a clean, gallery-like electrical hub. It’s a smart, essential detail that elevates everyday living with dependable sophistication.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eChoose the QO115CP for fast installation and dependable 15A protection—upgrade your panel with confidence today.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/f41112ec-a548-43be-a07c-804ac00e384a_8f9f0790-3413-46f5-a5b1-ca7c437ac987.pdf?v=1763435911\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/1e8fedd3-8545-481d-9ed8-5552dcc78ed6_e9992f16-34f0-46e8-a471-40e72a20bfae.pdf?v=1763435914\" target=\"_blank\"\u003eInstallation\u003c\/a\u003e\u003c\/p\u003e\n    ","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52410691322223,"sku":"QO115CP","price":16.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/square-d-circuit-breakers-qo115cp-64_1000_2cac3e72-99b9-4637-b8e5-a0d2c7f27f63.jpg?v=1763435925","url":"https:\/\/soporarbor.shop\/products\/100061177-qo-15-amp-single-pole-circuit-breaker","provider":"Super Arbor","version":"1.0","type":"link"}