{"product_id":"100076261-qo-2-15-amp-single-pole-class-ctl-tandem-circuit-breaker","title":"QO 2-15 Amp Single-Pole Class CTL Tandem Circuit Breaker","description":"\n    \u003ch1\u003eQO 15A Single-Pole Tandem Circuit Breaker\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eCompact tandem breaker provides two 15A single-pole circuits in one QO space for overload and short-circuit protection. Rated 120\/240V with 10k AIR and thermal-magnetic trip, designed for compatible Square D QO load centers and panels.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSpace-Saving Tandem:\u003c\/strong\u003e Two 15A single-pole circuits fit into one QO breaker space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Protection:\u003c\/strong\u003e Thermal-magnetic trip guards against overloads and short-circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Plug-On Mounting:\u003c\/strong\u003e Installs quickly in compatible Square D QO panels, CSEDs, and NQOD boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisi-Trip Indicator:\u003c\/strong\u003e Red visual cue makes tripped breaker identification fast\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Performance:\u003c\/strong\u003e 10k AIR, 120\/240V rating for residential applications\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/1bd52042-c050-4a7e-808b-a1315ad6fedc_b8238c13-0de2-4f40-b3e5-a90e1a2a78a7.pdf?v=1763435912\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTandem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A (each pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC \/ AIR Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed; ANSI compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Will this fit any Square D panel?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It fits only Square D QO load centers and panels that accept tandem breakers; it will not fit Homeline or QO spaces that do not allow tandems.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the voltage and interrupt rating?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Rated for 120\/240 VAC with a 10,000 AIC (AIR) interrupt rating.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How many circuits does it provide?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It provides two independent 15A single-pole circuits in one breaker space.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is there a visual trip indicator?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, QO breakers feature a red Visi-Trip indicator to quickly identify a tripped breaker.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What type of trip mechanism is used?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Thermal-magnetic trip for reliable protection.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eStreamlined Power, Minimal Footprint\u003c\/h2\u003e\n    \u003cp\u003eThis sleek tandem breaker brings order and efficiency to the heart of your home’s electrical canvas. Its space-saving form and crisp Visi-Trip detail offer a smart, functional accent inside the panel. Pair with a thoughtfully labeled load center to keep the system visually clean and effortlessly navigable. Consider it an essential touch for modern, luxe utility—beauty in precision and performance.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eOptimize your panel space and upgrade protection with this QO tandem breaker today.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/f41112ec-a548-43be-a07c-804ac00e384a_2132648a-9bef-4c29-afc9-a488e9519ac0.pdf?v=1763435907\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/8166f371-55db-4cc4-b69b-e279c28003c6_66dd0dea-5cec-4c68-ba68-4a81f74a2f24.pdf?v=1763435910\" target=\"_blank\"\u003eInstallation\u003c\/a\u003e\u003c\/p\u003e\n    ","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52410691125615,"sku":"QOT1515CP","price":33.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/square-d-circuit-breakers-qot1515cp-64_1000_796cb595-72d2-4a7a-bd19-c8c8402169f8.jpg?v=1763435919","url":"https:\/\/soporarbor.shop\/products\/100076261-qo-2-15-amp-single-pole-class-ctl-tandem-circuit-breaker","provider":"Super Arbor","version":"1.0","type":"link"}