{"product_id":"ge-60-amp-double-pole-ground-fault-breaker-with-self-test","title":"GE 60 Amp Double Pole Ground Fault Breaker with Self-Test","description":"\u003ch1\u003e60 Amp Double Pole GFCI Breaker with Self-Test\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eEnhance your electrical install with the GE 60 Amp Double Pole Ground Fault Circuit Breaker featuring automatic self-testing. This advanced GFCI breaker consistently checks ground circuitry, ensuring safety by preventing electrical shocks. Its corrosion-resistant tin-plated copper stab connection guarantees durability and reliability, making it a must-have for both pros and avid DIYers.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSelf-Test GFCI:\u003c\/strong\u003e Runs automatic diagnostics to ensure constant functionality of ground fault circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant:\u003c\/strong\u003e Tin-plated copper stab connection for long-lasting reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Safety:\u003c\/strong\u003e Provides protection against overloads, short circuits, and low-level electrical leakages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Indicator:\u003c\/strong\u003e Instantly alerts to faults, enhancing safety and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Supports both 8-3 Cu and 8-3 Al wire sizes.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterruption Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Amperage (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Distribution Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrip Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Weight (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.858 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerMark Gold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications and Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA Listed,UL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year warranty from first use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Depth (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Height (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How do I install the GE 60 Amp GFCI breaker?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e To install, ensure the power is off at the main panel. Follow the manufacturer's instructions, typically involving pigtail connections to the panel and attaching the breaker to the existing bus.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What happens during the self-test function?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The self-test function automatically checks the operational integrity of the ground circuit. If a fault is detected, it will trip and may need resetting or replacement.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Can this breaker be used outdoors?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The breaker itself should be housed inside a panel suited for outdoor use to protect against the elements.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is the GE GFCI breaker suitable for residential use?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is designed for residential applications, providing essential ground fault protection to home electrical systems.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Does this product come with a warranty?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it includes a one-year warranty from the first use.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eElevate Your Home's Electrical Safety with GE\u003c\/h2\u003e\n    \u003cp\u003eImagine a home where safety is seamlessly integrated into every design element. The GE 60 Amp Double Pole GFCI Breaker ensures that your electrical system is not only effective but also enhances your home's safety with sophistication. Its modern functionality and reliable construction make it a discreet but vital component of your home's backbone. Embrace this innovative breaker as an essential piece of your luxurious, smoothly operating household.\u003c\/p\u003e\n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eChoose the GE 60 Amp Ground Fault Breaker today to secure your home with unparalleled safety and reliability.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/8edfdb3b-87c0-4739-af8f-b61adba24160_7082e550-fe01-4a74-9985-c32517767f93.pdf?v=1735282991\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":52400821338479,"sku":"THQL2160GFT2P","price":111.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/ge-circuit-breakers-thql2160gft2p-64_1000_d8e78854-b3ce-4f62-9530-50c13016420a.jpg?v=1763182018","url":"https:\/\/soporarbor.shop\/products\/ge-60-amp-double-pole-ground-fault-breaker-with-self-test","provider":"Super Arbor","version":"1.0","type":"link"}