{"product_id":"thql1115afp2","title":"GE Q-Line THQL 15-Amp 1-Pole Combination Arc Fault Circuit Breaker","description":"\n    \u003ch1\u003e15A Single-Pole Combination AFCI Breaker\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eThis GE Q-Line combination arc fault circuit breaker provides CAFCI protection for 120V branch circuits, helping detect and mitigate both parallel and series arc faults to reduce the risk of electrical fires. Designed for plug-on installation with a pigtail neutral, it fits GE\/ABB residential load centers and delivers reliable performance in a compact 1-inch frame.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComprehensive Arc-Fault Protection:\u003c\/strong\u003e CAFCI design detects parallel and series arcs to help prevent electrical fires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Panel Compatibility:\u003c\/strong\u003e Plug-on breaker with pigtail neutral for GE\/ABB residential panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Build:\u003c\/strong\u003e Heat-resistant thermoset case and tin-plated copper stabs for a stable, corrosion-resistant connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Trip Indication:\u003c\/strong\u003e Trips to center position with front test button for quick diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Safety:\u003c\/strong\u003e Meets NEMA standards and is ANSI and CSA certified\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle (1-Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterruption Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFCI (Combination Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line THQL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePigtail neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 in x 4.15 in x 6.45 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed; ANSI and CSA listed; Meets NEMA standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-resistant thermoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStab Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTin-plated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBox-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrips to center position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year from first use\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What panels is this breaker compatible with?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is compatible with GE and ABB residential load centers that accept Q-Line THQL breakers.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What type of protection does this provide?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is a combination AFCI (CAFCI) that protects against both series and parallel arc faults on 120V branch circuits.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How is it installed?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It mounts as a plug-on breaker and includes a pigtail neutral lead that connects to the panel’s neutral bar.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the interrupting rating (AIC)?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e 10,000 AIC.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is it UL listed?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is UL Listed and meets NEMA standards.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eQuiet Confidence for a Safer, Smarter Home\u003c\/h2\u003e\n    \u003cp\u003eA sleek, compact safeguard tucked into your panel, this GE Q-Line breaker elevates everyday living with discreet reliability. I love the crisp, purposeful design—its center-trip indicator and test button bring clarity and control. Pair it with a well-labeled, organized load center to keep your electrical core as refined as the rooms it powers. Safety with style is the true foundation of luxurious living.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eUpgrade to CAFCI protection today for safer circuits and dependable performance in your GE\/ABB panel.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/ff549a42-f1e1-4130-aea4-001704c1e777_47d02ddf-02f8-49a2-8ab5-fc6de26a1315.pdf?v=1759340645\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/soporarbor.shop\/cdn\/shop\/files\/9fbebca4-7bbf-4fef-9608-64ebac47704f_ac975fff-1e98-44df-b2e9-e3a37fb5943c.pdf?v=1759340649\" target=\"_blank\"\u003eInstallation\u003c\/a\u003e\u003c\/p\u003e\n    ","brand":"GE","offers":[{"title":"Default Title","offer_id":46899802898747,"sku":"THQL1115AFP2","price":57.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/ge-circuit-breakers-thql1115afp2-64_1000_a7881eef-2d19-4904-898f-8758e302b4ea.jpg?v=1763132891","url":"https:\/\/soporarbor.shop\/products\/thql1115afp2","provider":"Super Arbor","version":"1.0","type":"link"}